NTS ULTRAPURE
HYDROGEN GENERATORS
NTS UltraPure
Hydrogen Generators
Carrier Grade
Utilizing our proprietary Proton Exchange Membrane (PEM) inside a 100% titanium cell provides superior generator performance and cell longevity. The permeation membrane drying system eliminates the requirement for desiccant cartridges along with the associated downtime and cost. The final purification stage uses a no maintenance cold dual dynamic regeneration system which increases the purity to +99.99996%. Innovative software control allows unrivaled operational performance and safety as well as the additional options of auto water feed, remote networking and cascading for built in redundancy.
NTS UltraPure Features
- Flow rate: 100 to 1350 mL/min
- Purity: >99.99996%
- Pressure: up to 11 barg (160 psig)
- Unique patented automatic dryer system
- Unique 100% titanium electrolytic cell
- No maintenance
- 2-year standard warranty
Application
NTS UltraPure
- GC carrier gas
- GC/MS carrier gas
- GC fuel gas
- GC-ELCD & HALL reaction gas
Analyzer Applications
- Total Hydrocarbon Analyzer (THA) fuel gas
- Chemisorption/ Physisorption measurement gas
Spectroscopy Applications
- ICP-MS Collision cell reaction gas
AID Deposition Process
- Plasma cleaning instrumentation (UCP)
- High-Efficiency Process Gas
- Hydrogenation Reactors
- Hydrogen Fuel Cells
- Weather Balloon Filling
- Electronic Nose (eNOSE)
- 2-D Chromatography
- 3-D Chromatography
Specifications
Models & Specs
NTS Ultra
Pure 100
NTS Ultra
Pure 160
NTS Ultra
Pure 250
NTS Ultra
Pure 300
NTS Ultra
Pure 400
NTS Ultra
Pure 500
NTS Ultra
Pure 600
NTS Ultra
Pure 1000
NTS Ultra
Pure 1350
Flow mL/min
100
160
250
300
400
500
600
1000
1350
Purity
+ 99.99996 – 99,99999 %
Dew point at 7 barg (100 psig)
Outlet pressure
barg (psig)
1.4 to 11 (20 to 160)
Technology
PEM (Proton Exchange Membrane) - 100% Titanium cell
Drying system
No Maintenance Cold Dual Dynamic Regeneration System
Deionized water
quality
Minimum < 1 micro S/cm @25°C - 1 Mohm-cm @25°C - ASTM II
Recommended < 0.2 microS/cm @25°C - 5 Mohm-cm @25°C - ASTM II
Internal water tank (liters)
2,5
Safety
Automatic shut down - internal/external hydrogen leak, overpressure and low water
Display
Touch screen with operating parameters, system status and safety alarms
LED indicators
Power on/off, system ready, errors
Interface
USB mod A
Electrical supply
110-120V 60Hz / 220-240V 50Hz
Power consumption
(watts)
100
120
165
205
210
220
255
385
410
Dimensions mm
(inches)
230W x 480H x 370D (9W x 19H x 15D)
Weight kg (lbs)
14
(31)
14
(31)
15
(33)
15
(33)
15
(33)
16
(35)
16
(35)
17
(37.5)
17
(37.5)
Shipping dimensions
mm (in)
580W x 570H x 400D (22.8W x 22.4H x 15.7D)
Shipping weight kg (lbs)
18
(39.5)
18
(39.5)
19
(42)
19
(42)
19
(42)
20
(44)
20
(44)
21
(46)
21
(46)
Outlet connection
1/8" Compression
Certification
CE, FCC, MET (UL and CSA compliant)
OPTIONS
Auto water refill
Continuous water feed from an external water supply
Cascading
Up to 10 units – built in redundancy for guaranteed up-time
Interface
RS232/RS485, external contacts, PC control and intranet
Options and Consumables
Code
Options
NTS12310154
I/O BOARD FOR NTS ULTRAPURE / STANDARD GENERATORS
NTS45610157
CABLE FOR CASCADING ALL VERSIONS, 2M LONG (I/O BOARD REQUIRES)
NTS456PH200-107
REMOTE CONTROL RS232 CABLE+PC SOFTWARE (I/O BOARD REQUIRES)
NTS345PH200-108
REMOTE CONTROL USB CABLE +PC SOFTWARE
NTS555PH200-109
AUTO REFILL PLUS (I/O BOARD REQUIRES)
NTS66610159
AUTO REFILL TUBING KIT, SET A AND B FOR 2 UNITS IN CASCADING
NTS77710160
AUTO REFILL TUBING EXTENSION KIT, SET C TO ADD 1 MORE UNITIN CASCADING
NTS112CASC-001
CASCADING HARDWARE KIT
NTS131CASC-002
ON/OFF & NON-RETURN VALVE
NTS242CASC-003
BUFFER RESERVOIR 0.75 LITERS
NTS543CASC-004
PRESSURE REGULATOR WITH PRESSURE GAUGE
NTS666CASC-005
CASCADING HARDWARE KIT (HIGH PURITY)
NTS878CASC-006
PRESSURE REGULATOR WITH PRESSURE GAUGE (HIGH PURITY)
Code
Consumables
NTS885H200-031
DEIONIZER BAG (PACK OF 2 PCS.)
Maintenance
Code
Options
NTS88710573
3-YEAR PREVENTIVE MAINTENANCE KIT FOR NTS ULTRAPURE HYDROGEN GENERATOR
NTS UltraPure Rack
Hydrogen Generators
Carrier Grade
The NTS UltraPure Rack Hydrogen Generator uses the latest proton exchange membrane (PEM) technology to produce high purity hydrogen. The exclusive “No Maintenance” gas column cold regeneration system eliminates all the down time for maintenance that is typical of other systems on the market, assuring the best hydrogen purity at all times.
ZERO AIR OPTION
This model has a
Zero Air option.
NTS UltraPure Rack Features
- Flow rate: 100 - 1350 mL/min
- Purity: >99.99996%
- Zero air flow rates: up to 5 L/min
- Zero air purity: <0.1 ppm of hydrocarbons
- Pressure: up to 11 barg (160 psig)
- Unique patented membrane drying system
- Proprietary 100% titanium cell technology
- USB connectivity
- 2-year complete cell and product warranty
Application
Analyzer Applications
- Process GC analyzers detector fuel, oxidant gas
- Emissions test analyzers fuel gas, oxidant gas
- Stack gas analyzers fuel gas, oxidant gas
Other Lab Applications
- On-board gas supply for mobile laboratories
Options
Zero Air Option 1.8 L/Min or 5 L/Min
- I/O board
- Remote control software (RS232 or USB)
- Cascading hardware (standard or high purity)
- Refill station (water tank) 3U or 2U
- Rack enclosure
Specifications
Models & Specs
NTS Ultra
Pure 100 Rack
NTS Ultra
Pure 160 Rack
NTS Ultra
Pure 250 Rack
NTS Ultra
Pure 300 Rack
NTS Ultra
Pure 400 Rack
NTS Ultra
Pure 500 Rack
NTS Ultra
Pure 600 Rack
NTS Ultra
Pure 1000 Rack
NTS Ultra
Pure 1350 Rack
Flow mL/min
100
160
250
300
450
500
600
1000
1350
Purity
+ 99.99996 %
Dew point at 7 barg (100 psig)
Outlet pressure
barg (psig
1.4 to 11 (20 to 160)
Technology
PEM (Proton Exchange Membrane) - 100% Titanium cell
Drying system
No Maintenance Cold Dual Dynamic Regeneration System
Deionized water
quality
Minimum < 1 micro S/cm @25°C - 1 Mohm-cm @25°C - ASTM II
Recommended < 0.2 microS/cm @25°C - 5 Mohm-cm @25°C - ASTM II
Internal water tank (liters)
2,5
Safety
Automatic shut down - internal/external hydrogen leak, overpressure and lowwater
Display
Touch screen with operating parameters, system status and safety alarms
LED indicators
Power on/off, system ready, errors
Interface
USB mod A
Electrical supply
110-120V 60Hz / 220-240V 50Hz
Power consumption
(watts)
90
115
125
150
180
200
300
400
500
Dimensions mm
(inches)
19” rack W - 3U H - 500 D (19.6)
Weight kg (lbs)
19 (41.9)
21 (46.2)
21 (46.2)
22 (48.5)
Shipping dimensions
mm (in)
720W x 375H x 565D (28.3W x 14.7H x 22.2D)
Shipping weight kg (lbs)
23 (50)
25 (55)
25 (55)
26 (57)
Outlet connection
1/8" Compression
Certification
CE, FCC, MET (UL and CSA compliant)
OPTIONS
Zero Air module
1.8 or 5 L/min
External water tank
19” rack 5 liter (2U) or 10 liter (3U) tank
Cascading
Up to 10 units – built in redundancy for guaranteed up-time
Interface
RS232/RS485, external contacts, PC control and intranet
Options and Consumables
Code
Options
CATALYST MODULE 1800 FOR RACK
NTS456RH-1800
ZERO AIR OPTION 1.8 L/MIN FOR RACK
CATALYST MODULE 5000 FOR RACK
NTS868RH-5000
ZERO AIR OPTION 5.0 L/MIN FOR RACK HYDROGEN GENERATORS
WATER INLET VALVE
NTS986RH-200-020
REFILL VALVE (FOR H2O PRESSURE LINES)
RACK WATER TANK 3U
NTS368RT3U
RACK WATER TANK 3U, REFILL STATION 3U FOR NTS ULTRAPURE
RACK GENERATORS
RACK WATER TANK 2U
NTS890RT2U
RACK WATER TANK 2U, REFILL STATION 2U FOR NTS ULTRAPURE
RACK GENERATORS
NTS890RT2U
NTS35910155
I/O BOARD FOR NTS ULTRAPURE RACK/FID
NTS890RT2U
NTS45610157
CABLE FOR CASCADING (I/O REQUIRES)
NTS890RT2U
NTS456PH200-107
REMOTE CONTROL RS232 (CABLE+PC SOFTWARE)
(REQUIRES I/O BOARD)
NTS890RT2U
NTS345PH200-108
REMOTE CONTROL USB CABLE+PC SOFTWARE
NTS890RT2U
NTS112CASC-001
CASCADING HARDWARE KIT
NTS890RT2U
NTS131CASC-002
ON/OFF & NON-RETURN VALVE (HP)
NTS890RT2U
NTS242CASC-003
BUFFER RESERVOIR 0.75 LITERS (HP)
NTS890RT2U
NTS543CASC-004
PRESSURE REGULATOR WITH PRESSURE GAUGE
NTS890RT2U
NTS666CASC-005
CASCADING HARDWARE KIT (HIGH PURITY)
NTS890RT2U
NTS878CASC-006
PRESSURE REGULATOR WITH PRESSURE GAUGE (HIGH PURITY)
NTS890RT2U
NTS226RH-200-022
H2 PIPE FITTING KIT 1/8” FOR ANY ADDITIONAL RACK UNIT
Code
Consumables
NTS885H200-031
DEIONIZER BAG (PACK OF 2 PCS.)
NTS86410161
REPLACEMENT CARTRIDGE FOR COALESCENT FILTER AF20
Maintenance
Code
Options
NTS99910428
3-YEAR PREVENTIVE MAINTENANCE KIT FOR NTS ULTRAPURE RACK / FID-T/FID-S, WITHOUT AIR FILTER
NTS64810283
3-YEAR PREVENTIVE MAINTENANCE KIT FOR NTS ULTRAPURE RACK / FID-T/FID-S, WITH AIR FILTER
Mandatory 3-year kits
Code
Options
NTS85710437
3-YEAR PREVENTIVE MAINTENANCE KIT 1.8L/MIN FOR ZERO AIR RACK, FID-STATION
NTS38610438
3-YEAR PREVENTIVE MAINTENANCE KIT 5.0 L/MIN FOR ZERO AIR RACK, FID-STATION
NTS UltraPure FID STATION
Hydrogen Generators
Carrier Grade
The NTS UltraPure FID STATION Hydrogen Generator uses the latest proton exchange membrane (PEM) technology to produce pure hydrogen at a flow rate from 100 to 1350 mL/min. The horizontal format is designed to sit under and support the weight of your GC, optimizing bench space. At only 150 mm (6 inches) high, the generator will still allow easy access to the injectors of any GC on the market.
BUILT-IN ZERO AIR FLOW OPTIONS:
1.8 L/min or 5 L/min
NTS UltraPure Fid Station Features
- Flow rate: 100 - 1350 mL/min
- Zero air option: 1.8 L/min or 5 L/min
- Purity: >99.99996%;
- Purity hydrocarbons + CO <0.1 ppm
- Pressure: up to 11 barg (160 psig)
- Unique Nafion membrane drying system
- Proprietary 100% titanium cell technology
- USB connectivity
- 2-year standard warranty
Application
GC Applications
- GC carrier gas
- GC/MS carrier gas
- GC fuel gas
- GC-ELCD & HALL reaction gas
Spectroscopy Applications
- ICP-MS Collision cell reaction gas
Analyzer Applications
- Total Hydrocarbon Analyzer (THA) fuel gas
- Chemisorption/Physisorption measurement gas
Other Applications
- Chemical vapor deposition instrumentation (CVD)
- Plasma cleaning instrumentation (UCP)
- High efficiency process gas
- Hydrogenation reactors
- Hydrogen fuel cells
- Weather balloon filling
- Electronic nose (eNose)
- 2-D chromatography
- 3-D chromatography
Specifications
Models & Specs
NTS Ultrapure
100 FID Station
NTS Ultrapure
300 FID Station
NTS Ultrapure
600 FID Station
NTS Ultrapure
1000 FID Station
NTS Ultrapure
1350 FID Station
Flow mL/min
100
300
600
1000
1350
Purity
>99.99996%
Outlet pressure barg (psig)
1.4 to 11 (20 to 160)
Technology
PEM (proton exchange membrane) - 100% titanium cell
Drying system
No maintenance cold dual dynamic regeneration system
Deionized water quality
Minimum <1 micro S/cm @ 25°C - 1 Mohm-cm @ 25°C - ASTM II
Recommended<0.2microS/cm @ 25°C - 5 Mohm-cm @ 25°C - ASTM II
Internal water tank (liters)
7
Safety
Automatic shut down - internal/external hydrogen leak, overpressure and low water
Display
Touch screen with operating parameters, system status and safety alarms
LED Indicators
Power on/off, system ready, errors
Interface
USB mod A
Electrical supply
110-120V 60Hz / 220-240V 50 Hz
Power Consumption (Watts)
90
150
300
400
450
Dimensions mm (in)
690W x 150H x 680D (27W x 6H x 26.7D)
Weight kg (lbs)
41 (90)
42 (92.5)
43 (95)
44 (97)
45 (99)
Shipping dimensions mm (in)
890W x 385H x 800D (35W x 15.1H x 31.4D)
Shipping weight kg (lbs)
47 (103)
48 (106)
49 (108)
50 (110)
51 (112)
Certification
CE, FCC, MET (UL and CSA compliant)
OPTIONS
- 1. Zero air option 1.8 L/min or 5 L/min;
- 2. I/O board;
- 3. Remote control software (RS232 or USB);
- 4. Cascading hardware (standard or high purity);
- 5. FID-station MS extension;
6. Automatic water refill.
ZERO AIR FLOW OPTIONS
NTS ULTRAPURE FID STATION-1800
NTS ULTRAPURE FID STATION-5000
Flow mL/min
1800
5000
Purity - hydrocarbons + CO
<0,1 ppm
Inlet pressure barg (psig)
4.5 to 10 (65 to 145)
Inlet air quality
Clean dry compressed air ISO8573-1:2010 Class 1.2.1
Max outlet pressure barg (psig)
5 (73)
Max HC in
100 ppm
Max CO in
50 ppm
Options and Consumables
Code
Options
CATALYST MODULE 1800 FOR FID-S
NTS780FH-1800
ZERO AIR OPTION 1.8 L/MIN
CATALYST MODULE 5000 FOR FID-S
NTS268FH- 5000
ZERO AIR OPTION 5.0 L/MIN
FID STATION MS EXTENSION
NTS006FH-MS
FID STATION MS EXTENSION
RACK WATER TANK 3U
NTS35910155
I/O BOARD
RACK WATER TANK 2U
NTS45610157
CABLE FOR CASCADING (2 METER LONG, REQUIRES I/O BOARD)
NTS890RT2U
NTS456PH200-107
REMOTE RS232 (REQUIRES I/O BOARD)
NTS890RT2U
NTS345PH200-108
REMOTE USB
NTS890RT2U
NTS112CASC-001
CASCADING KIT
NTS890RT2U
NTS131CASC-002
ON / OFF & NON RETURN VALVE
NTS890RT2U
NTS242CASC-003
BUFFER RESERVOIR 0.75 LITERS
NTS890RT2U
NTS543CASC-004
PRESSURE REGULATOR WITH PRESSURE GAUGE
NTS890RT2U
NTS666CASC-005
CASCADING HARDWARE KIT (HIGH PURITY)
NTS890RT2U
NTS878CASC-006
PRESSURE REGULATOR WITH PRESSURE GAUGE (HIGH PURITY)
Code
Consumables
NTS885H200-031
DEIONIZER BAG (PACK OF 2 PCS.)
NTS86410161
REPLACEMENT CARTRIDGE FOR COALESCENT FILTER AF10
Maintenance
Code
Options
NTS64810283
3-YEAR PREVENTIVE MAINTENANCE KIT FOR ULTRAPURE RACK/FID-T/FID-S, WITH AIR FILTER
Mandatory 3-year kits
Code
Options
NTS85710437
3-YEAR CATALYST REPLACEMENT KIT FOR 1.8 L/MIN ZERO AIR RACK, FID-STATION
NTS38610438
3-YEAR CATALYST REPLACEMENT KIT FOR 5.0 L/MIN ZERO AIR RACK, FID-STATION
NTS UltraPure FID TOWER
Hydrogen Generators
Carrier Grade
The space-saving NTS UltraPure FID Tower Hydrogen Generator uses the latest proton exchange membrane (PEM) technology to produce pure hydrogen. Deionized water is automatically loaded from smart internal system tanks with a 3-liter capacity, providing up to 3000 liters of H2 before a refill is required. The only recommended maintenance is simply replacing the internal deionizing cartridge.
Zero Air is built into the NTS Ultrapure FID Tower and you have two choices for flow rates: 1800 or 5000 ml/min. When ordering, be sure to select the Zero Air flow rate best suited to your needs.
NTS UltraPure FID TOWER Features
- Flow rate: 100 - 1350 mL/min
- Zero Air flow option: 1800 or 5000 ml/min
- Purity: >99.99996%;
- Purity hydrocarbons + CO: <0.1 ppm
- Pressure: up to 11 barg (160 psig)
- No maintenance cold dual dynamic regeneration drying system
- Proprietary 100% titanium cell technology
- USB connectivity
- 2-year standard warranty
Application
GC Applications
- GC carrier gas
- GC/MS carrier gas
- GC fuel gas
- GC-ELCD & HALL reaction gas
Spectroscopy Applications
- ICP-MS Collision cell reaction gas
Analyzer Applications
- Total Hydrocarbon Analyzer (THA) fuel gas
- Chemisorption/Physisorption measurement gas
Other Applications
- Chemical vapor deposition instrumentation (CVD)
- Plasma cleaning instrumentation (UCP)
- High efficiency process gas
- Hydrogenation reactors
- Hydrogen fuel cells
- Weather balloon filling
- Electronic nose (eNose)
- 2-D chromatography
- 3-D chromatography
Analyzer Applications
- Zero Air Option 1.8 L/min or 5 L/min
- I/O board
- Remote control software (RS232 or USB)
- Cascading hardware (standard or high purity)
- H2 Sensor
Specifications
Models & Specs
NTS UltraPure
100 FID TOWER
NTS UltraPure
160 FID TOWER
NTS UltraPure
250 FID TOWER
NTS UltraPure
300 FID TOWER
Flow, mL/min
100
160
250
300
Purity
> 99.99996 %
Dewpoint at 7 barg
(100 psig)
Technology
PEM (Proton Exchange Membrane) - 100% titanium cell
Drying systems
No maintenance cold dual dynamic regeneration system
Deionised water quality
Minimum < 1 micro S/cm @ 25°C - 1 Mohm-cm @ 25°C - ASTM II
Recommended < 0.2 microS/cm @ 25°C - 5 Mohm-cm @ 25°C - ASTM II
Internal water tank, liters
5
Safety
Automatic shut down - internal/external hydrogen leak, overpressure and lowwat
Display
Touch screen with operating parameters, system status and safety alarms
LED Indicators
Power on/off, system ready, errors
Electrical supply
110-120V 60Hz / 220-240V 50 Hz
Power consumption (watts)
90
115
140
150
Dimensions, mm (in)
140W x 490H x 580D (5.5W x 19H x 22.8D)
Weight kg (lbs)
23 (50)
24 (53)
Shipping dimensions mm (in)
770W x 590H x 410D (30.3W x 23.2H x 16.1D)
Shipping weight kg (lbs)
27 (59.5)
28 (62)
Operating temp oC (oF)
15 to 35 (59 to 95)
Certification
CE, FCC, MET (UL and CSA compliant)
Specifications
Models & Specs
NTS UltraPure
500 FID TOWER
NTS UltraPure
600 FID TOWER
NTS UltraPure
1000 FID TOWER
NTS UltraPure
1350 FID TOWER
Flow, mL/min
500
600
1000
1350
Purity
> 99.99996 %
Dewpoint at 7 barg (100 psig
Technology
PEM (Proton Exchange Membrane) - 100% titanium cell
Drying systems
No maintenance cold dual dynamic regeneration system
Deionised water quality
Minimum < 1 micro S/cm @ 25°C - 1 Mohm-cm @ 25°C - ASTM II
Recommended < 0.2 microS/cm @ 25°C - 5 Mohm-cm @ 25°C - ASTM II
Internal water tank, liters
5
Safety
Automatic shut down - internal/external hydrogen leak, overpressure and lowwat
Display
Touch screen with operating parameters, system status and safety alarms
LED Indicators
Power on/off, system ready, errors
Electrical supply
110-120V 60Hz / 220-240V 50 Hz
Power consumption (watts)
200
300
400
500
Dimensions, mm (in)
> 99.99996 %
Dewpoint at 7 barg (100 psig
140W x 490H x 580D (5.5W x 19H x 22.8D)
Weight kg (lbs)
25 (55)
26 (57)
Shipping dimensions mm (in)
770W x 590H x 410D (30.3W x 23.2H x 16.1D)
Shipping weight kg (lbs)
29 (64)
30 (66)
Operating temp oC (oF)
15 to 35 (59 to 95)
Outlet connection
1/8" Compression
Certification
CE, FCC, MET (UL and CSA compliant)
OPTIONS
- Zero Air is built into the NTS UltraPure FID TOWER. You will have two choices for the flow rates.